Load cells HBM PW6C-C3-5kg

 Product     |      2019-02-28 11:10

Single point load cells

Load cells HBM PW6C-C3-5kg
 

Special features

-- Accuracy class C3 with OIML-R60 test report
-- Off center load compensated (OIML R 76)
-- Max. capacities: 3 kg ... 40 kg
-- Degree of protection IP67 (according to EN 60 529)
-- Shielded connection cable
-- Optimized for static weighing applications
 
Optional:
-- Accuracy class C6 with OIML-R60 test report
-- Connection cable in six wire circuit
-- Different cable lengths
-- Aligned output, suitable for connection in parallel

Specifications

 
Type PW6C...
Accuracy class 1)
Maximum number of load cell intervals (nLC)
C3, C3MR
3000
Maximum capacity (Emax) kg 3 5 10 15 20 30 40
Minimum LC verification interval (vmin), (Accuracy class C3) g 0.5 1 2 2 5 5 10
Temperature effect on zero balance (TK0) (Accuracy class C3)  
% of Cn
/ 10K
0.0233 0.0280 0.0280 0.0186 0.0350 0.0233 0.0350
Minimum LC verification interval (vmin), (Accuracy class C3MR) g 0.2 0.5 1 1 2 2 5
Minimum LC verification interval (vmin) (Accuracy class C3MR)  
% of Cn
/ 10K
0.0093 0.0140 0.0140 0.0093 0.0140 0.0093 0.0175
Max. platform size mm 300 x 300
Sensitivity (Cn) mV/V
mV/V
2.2 0.2
Zero signal 0 0.12
Temperature effect on sensitivity (TKC) 2)
in the temperature range
+20 ... +40 °C [+68 ... +104 °F]
- 10 ... +20 °C [+14 ... +68 °F]
 
% of Cn
/ 10K
 
0.0175
0.0117
Relative reversibility error (dhy) 2) % of Cn
% of Cn
% of Cn
% of Cn
0.0166
Non-linearity (dlin) 2) 0.0166
Ratio of minimum dead load output return (DR) 0.0245
Off-center load error 3) 0.0233
Input resistance (RLC)
300...500
Output resistance (R0) 300...500
Reference excitation voltage (Uref) V
V
5
Nom. range of excitation voltage (BU) 1 ... 12
Isolation resistance (Ris) at 100 VDC GΩ > 2
Nominal (rated) range of ambient temperature (BT) °C [°F]
°C [°F]
°C [°F]
- 10 ... +40 [+14 ... +104]
Operating temperature range (Btu) - 10 ... +50 [+14 ... +122]
Storage temperature range (Btl) - 25 ... +70 [- 13 ... +158]
Limit load (EL) *)
*) at max. eccentricity
%
of Emax mm
%
150
 
100
Lateral load limit (Elq), static of E% of E 300
Breaking load (Ed) 300
Nominal (rated) displacement at Emax
(snom), approx.
mm < 0.5
Weight (G), approx. kg 0.25
Degree of protection acc. to EN 60 529 (IEC 529)   IP67
Material: Measuring body
Application protection Cable sheath
  Aluminum
Silicone rubber PVC
1)  According to OIMLR60 with PLC = 0.7
2)  The values for linearity deviation (dlin), relative reversibility error (dhy) and temperature effect on sensitivity (TKC) are recommended values. The sum of these values remain within the cumulated error limit acc. to OIML R60.
3)  According to OIML R76.