Load cells HBM Z6FC3-100kg

 Product     |      2019-03-01 11:33
Special features
 
-    Welded-on metal bellows
-    Maximum capacities: 5 kg … 1 t
-    Load cells and mounting aids made of rust-resistant materials
-    Legal for trade up to 6000 parts, test report to OIML R60
-    Six-wire configuration
-    Optimized for parallel connection
-    Meets EMC requirements in accordance with DIN EN 45501:2015
-    Options:
Explosion protection to ATEX and IECEx, FM (US) and EAC





Specifications
 
Type   Z6(F/G)D1 Z6(F/G)C3 Z6FC4 Z6FC6
Accuracy class to OIML R 60   D1 C3 C4 C6
Number of load cell verification intervals (nLC)   1000 3000 4000 6000
Maximum capacity (Emax) kg 5; 10; 20; 30; 50;
100; 200; 500
10; 20; 30; 50; 100;
200; 500
20; 30; 50;
100; 200; 500
20; 30; 50;
100; 200
t 1 1 - -
Minimum load cell verification interval (vmin)  
% of Emax
0.036 0.009
0.0083 (30 kg)
0.0066 0.0066
Y value 2778 11111
12000 (30 kg)
15000 15000
Accuracy class to NTEP IIIM1)
Number of load cell verification intervals (nLC)     5000    
Maximum capacity (Emax) kg   20; 30; 50; 100; 200    
Minimum load cell verification interval (vmin) % of Emax   Emax/11111 Emax/12000 (30 kg)    
General specifications
Nominal (rated) output (Cn) mV/V 2
Rated output tolerance with load appl. in stated direction % +(1;-0.1) T0.052)
Temperature coefficient of rated output (TKC)3)  
% of Cn/10 K
±0.0500 ±0.0080 ±0.0070 ±0.0040
Temperature coefficient of zero signal (TC0) ±0.0500 ±0.0125
±0.0116 (30 kg)
±0.0093 ±0.0093
Relative reversibility error (dhy)3)  
% of Cn
±0.0500 ±0.0170 ±0.0130 ±0.0080
Non-linearity (dlin)3) ±0.0500 ±0.0180 ±0.0150 ± 0.0110
Creep upon loading (dDR) in 30 min. ±0.0490 ±0.0166 ±0.0125 ±0.0083
Input resistance (RLC) Ù 350...480
Output resistance (R0) 356 ±0.2 356 ±0.12
Reference voltage (Uref)  
V
5
Nominal (rated) range of the excitation voltage (Bu) 0.5...12
Insulation resistance (Ris) > 5
Nominal (rated) range
of the ambient temperature (BT)
 
 
°C
-10...+40
Operating temperature range (Btu) -30...+70
Storage temperature range (Btl) -50...+85
Limit load (EL) % of Emax 150
Breaking load (Ed) Š300
1)   Load cells of OIML accuracy class C3 also conform to accuracy class NTEP (USA) IIIM 5000 with maximum capacities 20 to 200 kg. They therefore have a second NTEP label.
2)   For load cell Z6FC3/10kg: ≤ ±0.1 %.
3)   The values for non-linearity, relative reversibility error and temperature response of the output range are recommended values. If these values are added together, the total is within the accumulated error limit to OIML R60.